Product Overview The VOLTAPURE VP12-26Ah is a project-focused 12V 26Ah VRLA AGM battery for medium backup systems, fire and security installations, telecom cabinets, and multi-battery configurations. Its 12 mOhm internal resistance, 360A five-second discharge limit, and T4/T12 terminal options support demanding standby installations.
VOLTAPURE 12V 26Ah VRLA AGM Rechargeable Battery
SKU: VP12-26Ah
EGP 3,045.00Price
- • Battery technology: Rechargeable valve-regulated lead-acid (VRLA), AGM type • Nominal voltage: 12V • Rated capacity: 26Ah at the 20-hour rate • Capacity at stated rates: 20HR: 26Ah; 10HR: 24Ah; 1HR: 16Ah • Terminal type: T4/T12 • Internal resistance: Approx. 12 mOhm, fully charged at 25 degrees C • Dimensions (L x W x H / TH): 175 x 166 x 125 / 125 mm • Approx. weight: 7.90 kg, tolerance +/-4% • Maximum charging current: 7.8A • Maximum discharge current: 360A for 5 seconds • Float charging voltage: 13.50-13.80V at 25 degrees C; compensation -18mV/degree C • Cyclic charging voltage: 14.50-15.00V at 25 degrees C; compensation -30mV/degree C • Nominal operating temperature: 25 degrees C +/-3 degrees C • Operating temperature range: Discharge: -15 to +50 degrees C; charge: -10 to +50 degrees C; storage: -20 to +50 degrees C • Capacity by temperature: 40 degrees C: 102%; 25 degrees C: 100%; 0 degrees C: 85%; -15 degrees C: 65% • Self-discharge at 25 degrees C: Remaining capacity: 91% after 3 months; 82% after 6 months; 65% after 12 months • Designed float life: 5 years at 20 degrees C under specified float conditions • Construction: Lead-dioxide positive plate, lead negative plate, ABS container and cover, AGM separator, sulfuric-acid electrolyte, rubber safety valve, copper terminal
- • 26Ah capacity at the 20-hour rate for project and multi-battery systems. • AGM VRLA construction is sealed and requires no routine electrolyte top-up. • T4/T12 terminal configurations support compatible project connections. • Low 12 mOhm internal resistance supports effective high-rate output. • 360A five-second maximum discharge current for short peak demands within specification. • 7.8A maximum charging-current specification supports controlled charger selection. • Low self-discharge supports standby duty and planned storage. • Five-year design float life at 20 degrees C under specified conditions.
- • Medium backup-power systems • Fire-alarm and security installations • Telecom cabinets • Industrial control systems • Series or parallel battery banks designed for compatible VRLA AGM batteries
- • A compact block format delivers 26Ah capacity without moving directly to the larger 40Ah battery class. • The 360A peak limit and low internal resistance provide strong short-duration output for demanding backup loads. • T4/T12 terminal options support secure connections appropriate for project installations. • Published charge, temperature, self-discharge, and internal-resistance data improve engineering confidence over generic batteries with limited specifications. • VOLTAPURE provides documented OEM performance with local availability and support from Maamoon Est. in Egypt.